PIPE CULVERTS

Classes of Reinforced Concrete Pipe for the Respective Diameters of Pipe and Fill Heights over the Top of Pipe (Metric)

. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7
Nominal Diameter mm Fill Height:
Greater than 0.3 m  Not exceeding
1 m
Fill Height:
Greater than 1 m Not exceeding
3 m
Fill Heights:
Greater than 3 m Not exceeding 4.5 m
Fill Height:
Greater than 4.5 m Not exceeding
6 m
Fill Height:
Greater than 6 m Not exceeding 7.5 m
Fill Height:
Greater than 7.5 m Not exceeding
9 m
Fill Height:
Greater than 9 m  Not exceeding
10.5 m
300
IV II III IV V V V
375
450
IV
IV
II
II
III
III
IV
IV
V
IV
V
V
V
V
525
600
750
825
IV
IV
IV

IV
II
II
II
II
III
III
III
III
IV
IV
IV
IV
IV
IV
IV
IV
V
V
V
V
V
V
V
V
900
1050
1200
III
III
II
II
II
II
III
III
III
IV
IV
IV
IV
IV
IV
V
V
V
V
V
V
1350
1500
1650
II
I
I
II
II
II
III
III
III
IV
IV
IV
IV
V
V
V
V
V
V
V
V
1800
1950
2100
I
I
I
I
I
I
III
III
III
IV
IV
IV
V
*V
*V
V
*V
*V
V
*V
*V
2250
2400
2550
2700
I
I
I
I
I
I
I
I
III
III
III
III
*IV
*IV
*IV
*IV
*V
*V
*V
*V
*V
*V
*V
*V
*V
*V
*V
*V

* Special Design Required